Photoconductive Infrared Detectors

PbS (SCD-13) and PbSe (SCD-15) Detectors

Cal Sensors has developed and is a volume producer of photoconductive lead sulfide (PbS) and lead selenide (PbSe) infrared detectors / Infrared Sensors which cover the 1 µm to 5.5 µm spectral region.

Our SCD-13 and SCD-15 IR detectors are manufactured via well established and superbly controlled processes, and because of their proven performance, have become the infrared detectors of choice by most system manufacturers worldwide.
 

  • PbS (SCD-13) Detectors
  • PbSe (SCD-15) Detectors

Lead Sulfide (PbS/SCD-13) Detectors

Photoconductive Infrared (IR) Detectors

This section is intended as a design guide to:

  • Outline products for which detector active area
    and package tooling exists
  • Describe typical ranges of readily available detector
    characteristics and performance

Detector Specifications:

IDA (Integrated IR Detector Assembly)
Uncooled SCD-13 Detectors (Ambient Packaged)
One Stage TEC SCD-13 Detectors (50° typical DT)
Two Stage (1.5W) TEC SCD-13 Detectors (60° typical DT)
Two Stage (2.5W) TEC SCD-13 Detectors (75° typical DT)


Lead Selenide (PbSe/SCD-15) Detectors

Photoconductive Infrared (IR) Detectors

This section is intended as a design guide to:
 

  • Outline products for which detector active area
    and package tooling exists
  • Describe typical ranges of readily available detector
    characteristics and performance

Detector Specifications:

IDA (Integrated IR Detector Assembly)
Uncooled SCD-15 Detectors (Ambient Packaged)
One Stage TEC SCD-15 Detectors (50° typical DT)
Two Stage (1.5W) TEC SCD-15 Detectors (60° typical DT)
Two Stage (2.5W) TEC SCD-15 Detectors (75° typical DT)

Multi Element Arrays

For applications that require multiple detector elements

MCD Array — For applications that require only a few detector elements, each element can be bonded to a dedicated package pin. These also include packages with multiple detector types.

  • Multi-Color Detectors :
    • Multi-Color Coplanar Detector Assemblies
    • Two Color Coaxial Detector Assemblies

     
  • Arrays to 64 Elements:
    • Arrays to 64 Elements - LMA-13R & LMA-15R
    • Drawings & Application Notes

LMA Array — For applications requiring a larger number of elements, multiplexing provides a convenient way to reduce the package pin count. Signal conditioning is also provided.

  • PbS Arrays
  • PbSe Arrays
  • Development Systems

Infrared Emitters: Cal-Source™

After years of extensive development and testing, Cal Sensors has developed low cost, high reliability pulsable and steady-state emitters specifically designed for use with infrared detectors.

Cal-Source infrared emitters, constructed with rugged, proven packaging techniques developed at Cal Sensors, offer a new level in state-of-the-art design and performance:

  • Rugged construction
  • High emissivity
  • Long lifetime
  • Low cost
  • UV through IR
  • Small size
  • Low power consumption

AP Series - Uncooled SCD-13 Detectors


 
Ambient Temperature: +23°C
Detector Operating Temperature +23°C
Detectors tested using 50 V/mm across the detector and a one Megohm load resistor in series. (except AP-1x3, AP-1x5, and AP-2x5 use 0.5 megohm load resistor.)
Standard Specifications - Electrical
  Minimum Typical Maximum Units
Wavelength of Max. Response 2.2 2.4   µm
D*(500K, 650 Hz, 1Hz) 7.5 x 108 9.4 x 108   cm Hz1/2 w-1
D*( lpk, 650 Hz, 1 Hz) 8.0 x 1010 1.0 x 1011   cm Hz1/2 w-1
Element Resistance (Dark) 0.5 1.0 2.0 Megohms/PbS Uncooled
Time Constant (not measured)   200 400 µsec
Rated Element Temperature     +65 °C

When using the table below, remove parenthesis and insert appropriate designation for package type in this space: Example: 3 for TO-3, 5 for TO-5, 8 for TO-8.

Model
Number
Element Size
(mm)
Responsivity
(lpk, 650) vw-1
Standard Package
Options
Minimum Typical
AP-1( ) 1 x 1 5.3 x 105 8.0 x 105 TO-5, TO-8
AP-1 x 3( ) 1 x 3 2.1 x 105 3.1 x 105 TO-5, TO-8
AP-1 x 5( ) 1 x 5 1.2 x 105 1.8 x 105 TO-5, TO-8
AP-2( ) 2 x 2 2.7 x 105 4.0 x 105 TO-5, TO-8
AP-2 x 5( ) 2 x 5 0.8 x 105 1.2 x 105 TO-5, TO-8
AP-3( ) 3 x 3 1.7 x 105 2.6 x 105 TO-5, TO-8
AP-48 4 x 4 1.3 x 105 2.0 x 105 TO-8
AP-58* 5 x 5 1.1 x 105 1.6 x 105 TO-8
AP-68* 6 x 6 9.0 x 104 1.4 x 105 TO-8
AP-103** 10 x 10 5.0 x 104 7.5 x 104 TO-3
* Minimum D*(lpk, 650, 1) >7.0 x 1010 cm Hz1/2 w-1
**
Minimum D*(lpk, 650, 1) >6.0 x 1010 cm Hz1/2 w-1
 

AT1 Series - One Stage TE Cooled SCD-13 Detectors

Ambient Temperature: +25°C
Detector Operating Temperature -25°C
Typical Cooler Power @/or near Max. Cooling: AT1 - 1.0 volts @1.2 amps
AT1S - 1.8 volts @ 1.2 amps
Standard Specifications - Electrical
All detector specifications are at a bias voltage of 50 V/mm distance between electrodes applied across the detector and with a one megohm load resistor in series. All specifications apply at or near maximum cooling with the heat sink @ +25°C. 
  Minimum Typical Maximum Units
Wavelength of Max. Response 2.4 2.5   µm
D*(500K, 650 Hz, 1Hz) 1.0 x 109 1.5 x 109   cm Hz1/2 w-1
D*( lpk, 650 Hz, 1 Hz) 1.0 x 1011 1.5 x 1011   cm Hz1/2 w-1
Element Resistance (Dark) 1.5 3.0 10.0 Megohms/PbS One Stage
Time Constant (not measured)   800 1600 µsec
Rated Element Temperature     +65 °C
DT@/or near Max. Cooling 45 50   °C

For square or rectangular element sizes and/or packages not listed, please contact our application engineers,  phone (707) 303-3837, or fax (707) 545-5113.

When using the table below, remove parenthesis and insert appropriate designation for package type in this space: Example: 6 for TO-66, 7 for TO-37, 8 for TO-8.

Model
Number
Element Size
(mm)
Responsivity
(lpk, 650) vw-1
Standard Package
Options
Minimum Typical
AT1-1( ) 1 x 1 1.3 x 106 1.9 x 106 TO-37,TO-8
AT1-2( ) 2 x 2 6.3 x 105 9.5 x 105 TO-37,TO-8
AT1-3( ) 3 x 3 4.2 x 105 6.3 x 105 TO-37,TO-8
AT1S-4( ) 4 x 4 3.1 x 105 4.7 x 105 TO-66, TO-8
AT1S-5( )* 5 x 5 2.5 x 105 3.8 x 105 TO-66, TO-8
AT1S-6( )* 6 x 6 2.0 x 105 3.0 x 105 TO-66, TO-8
AT1S-103** 10 x 10 1.2 x 105 1.8 x 105 TO-3
* Minimum D*(lpk, 650, 1) >8.0 x 1010 cm Hz1/2 w-1
**
Minimum D*(lpk, 650, 1) >7.0 x 1010 cm Hz1/2 w-1 
  • To specify thermistor option for all TE cooled detectors, add the suffix -T or -TC (calibrated) to the model number.

AT2 Series - Two Stage (1.5W)
TE Cooled SCD-13 Detectors

Ambient Temperature:

+25°C
Detector Operating Temperature -35°C
Typical Cooler Power @/or near Max. Cooling: 0.9 volts @1.2 amps
Standard Specifications - Electrical
All detector specifications are at a bias voltage of 50 V/mm distance between electrodes applied across the detector and with a one megohm load resistor in series. All specifications apply at or near maximum cooling with the heat sink @ +25°C. 
  Minimum Typical Maximum Units
Wavelength of Max. Response 2.5 2.6   µm
D*(500K, 650 Hz, 1Hz) 1.6 x 109 2.7 x 109   cm Hz1/2 w-1
D*( lpk, 650 Hz, 1 Hz) 1.5 x 1011 2.5 x 1011   cm Hz1/2 w-1
Element Resistance (Dark) 2.5 5.0 15.0 Megohms/PbS Two Stage 1.5w
Time Constant (not measured)   1250 2500 µsec
Rated Element Temperature     +65 °C
DT@/or near Max. Cooling 55 60   °C

For square or rectangular element sizes and/or packages not listed, please contact our application engineers,  phone (707) 303-3837, or fax (707) 545-5113.

When using the table below, remove parenthesis and insert appropriate designation for package type in this space: Example: 6 for TO-66, 7 for TO-37, 8 for TO-8.

Model
Number
Element Size
(mm)
Responsivity
(lpk, 650) vw-1
Standard Package
Options
Minimum Typical
AT2-1( ) 1 x 1 1.3 x 106 2.0 x 106 TO-37, TO-8
AT2-2( ) 2 x 2 6.6 x 105 1.0 x 106 TO-37, TO-8
AT2-3( ) 3 x 3 4.3 x 105 6.4 x 105 TO-37, TO-8
AT2-4( )* 4 x 4 3.2 x 105 4.8 x 105 TO-37, TO-8
* Minimum D*(lpk, 650, 1) >1.0 x 1011 cm Hz1/2 w-1
  • To specify thermistor option for all TE cooled detectors, add the suffix -T or -TC (calibrated) to the model number.

AT2S Series - Two Stage (2.5W)
TE Cooled SCD-13 Detectors

Ambient Temperature: +25°C
Detector Operating Temperature See model types below
Typical Cooler Power @/or near Max. Cooling: 1.8 volts @1.2 amps
Standard Specifications - Electrical
All detector specifications are at a bias voltage of 50 V/mm distance between electrodes applied across the detector and with a one megohm load resistor in series. All specifications apply at or near maximum cooling with the heat sink @ +25°C.
  Minimum Typical Maximum Units
Wavelength of Max. Response 2.6 2.7   µm
D*(500K, 650 Hz, 1Hz) 2.2 x 109 3.3 x 109   cm Hz1/2 w-1
D*(lpk, 650 Hz, 1 Hz) 2.0 x 1011 3.0 x 1011   cm Hz1/2 w-1
Element Resistance (Dark) 3.0 6.0 20.0 Megohms/PbS Two Stage 2.5w
Time Constant (not measured)   1750 3500 µsec
Rated Element Temperature     +65 °C
DT@/or near Max. Cooling 70 75   °C

For square or rectangular element sizes and/or packages not listed, please contact our application engineers,  phone (707) 303-3837, or fax (707) 545-5113.

When using the table below, remove parenthesis and insert appropriate designation for package type in this space: Example: 6 for TO-66, 8 for TO-8.

Model
Number
Element Size
(mm)
Responsivity
(lpk, 650) vw-1
Operating Temp Standard Package
Options
Minimum Typical
AT2S-1( ) 1 x 1 1.4 x 106 2.1 x 106 -50°C TO-66, TO-8
AT2S-2( ) 2 x 2 7.0 x 105 1.1 x 106 -50°C TO-66, TO-8
AT2S-3( ) 3 x 3 4.3 x 105 6.5 x 105 -45°C TO-66, TO-8
AT2S-4( ) 4 x 4 3.3 x 105 5.0 x 105 -40°C TO-66, TO-8
AT2S-5( )* 5 x 5 2.7 x 105 4.0 x 105 -35°C TO-66, TO-8
AT2S-6( )* 6 x 6 2.4 x 105 3.6 x 105 -25°C TO-66, TO-8
* Minimum D*(lpk, 650, 1) >1.0x1011 cm Hz1/2 w-1

BXP Series - Uncooled SCD-15 Detectors

Ambient Temperature: +23°C
Detector Operating Temperature +23°C

Detectors tested using 35 V/mm across the detector and a one Megohm load resistor in series.

Standard Specifications - Electrical
  Minimum Typical Maximum Units
Wavelength of Max. Response 3.6 3.8   µm
D*(500K, 1000 Hz, 1Hz) 1.0 x 108 1.5 x 109   cm Hz1/2 w-1
D*( lpk, 1000 Hz, 1 Hz) 1.0 x 109 1.5 x 1010   cm Hz1/2 w-1
Element Resistance (Dark) 0.1 0.8 2.5 Megohms/PbSe Uncooled
Time Constant (not measured)   2 5 µsec
Rated Element Temperature     +85 °C
When using the table below, remove parenthesis and insert appropriate designation for package type in this space. Example: 5 for TO-5, 8 for TO-8.
Model
Number
Element Size
(mm)
Responsivity
(lpk, 1000) vw-1
Standard Package
Options
Minimum Typical
BXP-1( ) 1 x 1 1.5 x 104 3.0 x 104 TO-5,TO-8
BXP-2( ) 2 x 2 7.5 x 103 1.5 x 104 TO-5,TO-8
BXP-3( ) 3 x 3 5.0 x 103 1.0 x 104 TO-5,TO-8
BXP-48 4 x 4 3.75 x 103 7.5 x 103 TO-8
BXP-58 * 5 x 5 3.0 x 103 6.0 x 103 TO-8
BXP-68 * 6 x 6 2.5 x 103 5.0 x 103 TO-8
BXP-103** 10 x 10 1.5 x 103 3.0 x 103 TO-3
* Minimum D*( lpk, 1000 Hz, 1 Hz) > 8 x 109 cm Hz1/2 w-1
**
Minimum D*( lpk, 1000 Hz, 1 Hz) > 6 x 109 cm Hz1/2 w-1
1/4 x 1/4mm, 1/2 x 1/2mm, 1 x 3mm, 1 x 5mm & 2 x 5mm element sizes also available.

BXT1 Series - One Stage TE Cooled SCD-15 Detectors

Ambient Temperature: +25°C
Detector Operating Temperature -25°C
Typical Cooler Power @/or near Max. Cooling: BXT1 -1.0 volts @1.2 amps
BXT1S - 1.8 volts @ 1.2 amps
Standard Specifications - Electrical
All detector specifications are at a bias voltage of 25 V/mm distance between electrodes applied across the detector and with a load resistor in series. All specifications apply at or near maximum cooling with the heat sink @ +25°C.
  Minimum Typical Maximum Units
Wavelength of Max. Response 4.0 4.2   µm
D*(500K, 1000 Hz, 1Hz) 1.9 x 109 3.9 x 109   cm Hz1/2 w-1
D*( lpk, 1000 Hz, 1 Hz) 1.4 x 1010 2.8 x 1010   cm Hz1/2 w-1
Element Resistance (Dark) 0.5 4.0 10.0 Megohms/PbSe One Stage
Time Constant (not measured)   6 12 µsec
Rated Element Temperature     +55 °C
DT@/or near Max. Cooling 45 50   °C
Other detector configurations available upon request,
please contact our application engineers, phone (707) 303-3837,
or fax (707) 545-5113.

When using the table below, remove parenthesis and insert appropriate designation for package type in this space. Example: 5 for TO-5, 8 for TO-8.

Model
Number
Element Size
(mm)
Responsivity
(lpk, 1000) vw-1
Standard Package
Options
Minimum Typical
BXT1-1( ) 1 x 1 40000 60000 TO-37,TO-8
BXT1-2( ) 2 x 2 20000 30000 TO-37,TO-8
BXT1-3( ) 3 x 3 13300 20000 TO-37,TO-8
BXT1S-4( ) 4 x 4 10000 15000 TO-66, TO-8
BXT1S-5( )* 5 x 5 8000 12000 TO-66, TO-8
BXT1S-6( )* 6 x 6 6700 10000 TO-66, TO-8
BXT1S-103** 10 x 10 4000 6000 TO-3
* Minimum D*( lpk, 1000, 1) >1.0 x 1010 cm Hz1/2 w-1
** Minimum D*( lpk, 1000, 1) >8.0 x 109 cm Hz1/2 w-1 

BXT2 Series - Two Stage (1.5W)
TE Cooled SCD-15 Detectors


 
Ambient Temperature: +25°C
Detector Operating Temperature -35°C
Typical Cooler Power @/or near Max. Cooling: 0.9 volts @1.2 amps
Standard Specifications - Electrical
All detector specifications are at a bias voltage of 25 V/mm distance between electrodes applied across the detector and with a load resistor in series. All specifications apply at or near maximum cooling with the heat sink @ +25°C.
  Minimum Typical Maximum Units
Wavelength of Max. Response 4.1 4.3   µm
D*(500K, 1000 Hz, 1Hz) 2.2 x 109 4.2 x 109   cm Hz1/2 w-1
D*( lpk, 1000 Hz, 1 Hz) 1.6 x 1010 3.0 x 1010   cm Hz1/2 w-1
Element Resistance (Dark) 1.0 5.0 15.0 Megohms/PbSe Two Stage 1.5w
Time Constant (not measured)   9 20 µsec
Rated Element Temperature     +55 °C
DT@/or near Max. Cooling 55 60   °C
Other detector configurations available upon request,
please contact our application engineers, phone (707) 303-3837,
or fax (707) 545-5113.

When using the table below, remove parenthesis and insert appropriate designation for package type in this space. Example: 5 for TO-5, 8 for TO-8.

Model
Number
Element Size
(mm)
Responsivity
(lpk, 1000) vw-1
Standard Package
Options
Minimum Typical
BXT2-1( ) 1 x 1 66000 100000 TO-37,TO-8
BXT2-2( ) 2 x 2 33000 50000 TO-37,TO-8
BXT2-3( ) 3 x 3 22000 33000 TO-37,TO-8
BXT2-4( ) 4 x 4 16000 25000 TO-8

BXT2S Series - Two Stage (2.5W)
TE Cooled SCD-15 Detectors


 
Ambient Temperature: +25°C
Detector Operating Temperature See model types below
Typical Cooler Power @/or near Max. Cooling: 1.8 volts @1.2 amps
Standard Specifications - Electrical
All detector specifications are at a bias voltage of 25 V/mm distance between electrodes applied across the detector and with a load resistor in series. All specifications apply at or near maximum cooling with the heat sink @ +25°C.
  Minimum Typical Maximum Units
Wavelength of Max. Response 4.3 4.5   µm
D*(500K, 1000 Hz, 1Hz) 2.9 x 109 5.2 x 109   cm Hz1/2 w-1
D*( lpk, 1000 Hz, 1 Hz) 2.0 x 1010 3.5 x 1010   cm Hz1/2 w-1
Element Resistance (Dark) 1.0 6.0 20.0 Megohms/PbSe Two Stage 2.5w
Time Constant (not measured)   12 25 µsec
Rated Element Temperature     +55 °C
DT@/or near Max. Cooling Scroll to see chart below   °C
Other detector configurations available upon request,
please contact our application engineers, phone (707) 303-3837,
or fax (707) 545-5113.

When using the table below, remove parenthesis and insert appropriate designation for package type in this space. Example: 6 for TO-66, 8 for TO-8.

Model
Number
Element Size
(mm)
Responsivity
( lpk, 1000) vw-1
Operating Temp Standard Package
Options
Minimum Typical
BXT2S-1( ) 1 x 1 100000 150000 -50°C TO-66, TO-8
BXT2S-2( ) 2 x 2 50000 75000 -50°C TO-66, TO-8
BXT2S-3( ) 3 x 3 33000 50000 -45°C TO-66, TO-8
BXT2S-4( ) 4 x 4 25000 37500 -40°C TO-66, TO-8
BXT2S-5( )* 5 x 5 20000 30000 -35°C TO-66, TO-8
BXT2S-6( )* 6 x 6 16500 25000 -25°C TO-66, TO-8
* Minimum D*( lpk, 1000, 1) >1.5 x 1010 cm Hz1/2 w-1

LMA (Mux) LMA-13R Arrays

256 Element Array Integrating Multiplexer, Thermoelectric CoolerThe Cal Sensors 256 element linear array is specifically designed for low-cost spectroscopy from 1 to 3 microns. This industry standard, low profile package includes high aspect ratio pixels on 50 micron centers. The internal electronics provide variable integration and dark current correction. Temperature stabilization is achieved by an internal thermoelectric cooler and thermistor

Features

  • 256 element LMA-13R detector array
  • Sensitivity to 3 microns
  • High aspect ratio elements on 50 μm centers
     
  • Thermoelectric cooler with integrated thermistor
     
  • Industry standard low profile 28-pin package
     
  • Internal MUX with serial readout up to 2 MHz
     
  • Global plus 8 bit per pixel dark current correction
     
  • Signal Integration before or during readout
     
  • Variable integration with adjustable well size

LMA (Mux) LMA-15R Arrays

Multiplexed PbSe ArrayThe Cal Sensors 256 element linear array is specifically designed for low-cost spectroscopy from 1 to 5 microns. This industry standard, low profile package includes high aspect ratio pixels on 50 micron centers. The internal electronics provide variable integration and dark current correction. Temperature stabilization is achieved by an internal thermoelectric cooler and thermistor.

Features

  • 256 element LMA-15R detector array
     
  • Sensitivity to 5 microns
     
  • High aspect ratio elements on 50 μm centers
     
  • Thermoelectric cooler with integrated thermistor
     
  • Industry standard low profile 28-pin package
     
  • Internal MUX with serial readout up to 2 MHz
     
  • Global plus 8 bit per pixel dark current correction
     
  • Signal Integration before or during readout
     
  • Variable integration with adjustable well size

 

红外测温仪/红外热像仪 常用红外温度传感器系列 常用红外温度传感器及资料红外温度传感器模块摸组  红外线温度传感器一 红外线温度传感器二 红外线温度传感器 红外线温度传感器 四 红外测温模块红外测温模块二 红外测温模块 三 红外测温模块 四 红外热像红外气体分析红外行业应用红外相关配件红外技术资料 红外火焰探测器红外气体分析器件 红外气体分析原理

 热释电红外人体感应传感器系列产品/防盗报警配套元器件

 

红外传感器 RE200B KDS209、PIS209 LHI958LHI878 PD632
红外专用芯片

BISS0001

BISS0002

CS9803GP

KC778B

MB8072

HT7610

M7612

M7610

菲涅尔透镜

7601

7701

7703

7708

菲涅尔透镜选购资料

7709

7802

7803

7807

  7808 8002-1 8002-2 8102
透镜图片选型类

系列1

系列2

系列3

系列4

感应开关,报警器

GH-903

HT-807

GH-608

主动红外入侵探测器

  批量生产 人体红外感应模块

SS-101

红外火焰探测器

  安防防盗报警配套IC
红外出入口控制探测器 吸顶式被动红外探测器
被动红外幕帘式防盗探测器 被动红外探测器
长距离被动红外探测器 无限被动红外FR920
DS835IT 三技术红外探测器
吸顶式三技术红外探测器 长距离三技术红外探测器
光电对射探测器 单射束光电对射探测器
双射束光电对射探测器 四射束光电对射探测器
操作手册 红外测距传感器/距离测量传感器
紫外传感器 被动式红外传感器
汽车尾气四/五气模块 红外气体传感器
红外发射管 红外探测器
红外接收管 红外非接触测温传感器
红外非接触测温模块 非接触红外测温仪
热释电红外传感器 红外中断开关
光电编码元件 光电组件
红外中断开关 热电堆传感器
紫外光敏管、紫外光管、紫外光电管详细资料 红外发射二极管

SS-101红外线人体感应模块使用说明  SS-968微波感应模块/雷达探测模块使用说明  SS-9261微波感应模块/雷达探测模块使用说明

安防产品 主动红外 被动红外 门窗磁控感应器
其它产品 电子元器件产品 液位传感器 接近传感器
干簧管 磁簧继电器 光电传感器 液位开关
浮子      
CO 红外探测器   CH4红外探测器   CO2红外探测器   SF6红外探测器   SO2红外探测器 HC红外探测器 
红外光源   红外光电气体传感器  NDIR红外气体传感器  红外温度传感器  红外气体分析器件
CO2红外光源   CH4红外光源   CO红外光源   C3H8红外光源   C4H10红外光源   C2H4红外光源   C2H2红外光源      SF6红外光源   SO2红外光源   HC红外光源